Keep 21 CFR Part 11 audit trails and access controls inspection-ready
21 CFR Part 11 is the US Food and Drug Administration regulation that defines when electronic records and electronic signatures are considered trustworthy, reliable and equivalent to paper records and handwritten signatures. It applies to any record kept or submitted electronically under FDA requirements, and calls for validated systems, secure time-stamped audit trails, restricted access and controlled electronic signatures.
Is 21 CFR Part 11 right for your organisation?
Any organisation that creates, modifies, maintains, archives, retrieves or transmits FDA-required records in electronic form must meet Part 11, including drug, biologics, medical device and clinical trial sponsors, CROs and laboratories. Software and cloud suppliers to these organisations are routinely asked to show their systems support Part 11 controls before they are selected or audited.
It is a legal or regulatory requirement for organisations in scope.
- Issued by
- US Food and Drug Administration (FDA)
- Legal citation
- Title 21 Code of Federal Regulations, Part 11
- Published
- 20 March 1997 (62 FR 13464)
- In force since
- 20 August 1997
- Applies to
- Electronic records and signatures kept or submitted under FDA requirements
- Enforced through
- FDA inspections, Form 483 observations and warning letters
- Certification route
- None: compliance is shown through validation records and FDA inspection
- Type
- Regulation (mandatory)
- Region
- United States, US
- In OneClickComply
- Supported today
OneClickComply makes it simple
21 CFR Part 11 is mapped in OneClickComply's control library and available on request, so the access control, audit trail, password and change control requirements can be linked to controls you already run for frameworks such as ISO 27001 or SOC 2. Automated evidence collection and continuous monitoring keep proof of those technical controls current, while our audit team can advise on how they support your Part 11 programme.
Requirements covered
Three subparts with nine sections: general provisions (11.1 to 11.3), electronic records controls (11.10 to 11.70) and electronic signature controls (11.100 to 11.300), with the core closed system controls in 11.10(a) to (k).
Manual 21 CFR Part 11 vs. OneClickComply
- Pulling user access lists and audit trail settings from every system by hand before an inspection
- Keeping password, identity code and account deactivation controls consistent across tools
- Maintaining policies on electronic signature accountability that drift from how systems really work
- Repeating the same access control evidence for Part 11, ISO 27001 and customer audits
- Finding out that logging or access settings changed only when an auditor asks
- Access and logging evidence is collected automatically and kept ready for review
- Identity and password controls are monitored continuously across connected tools
- Policies are generated from your actual environment, so they match practice
- Controls are mapped once and the evidence counts towards every framework they apply to
- Drift alerts flag changed settings so they can be fixed before an inspection
Everything you need for 21 CFR Part 11
Map Part 11 sections 11.10, 11.100 and 11.300 to your existing security controls
Collect access review and user provisioning evidence automatically from identity tools
Monitor audit logging and alert when logging or retention settings drift
Generate access control, password and change control policies from your real environment
Track supplier risk for the GxP systems that hold your electronic records
Use OneClickFix to correct supported misconfigurations, with the change logged as evidence
Three steps to 21 CFR Part 11 compliance
Connect & scan
Connect your cloud, identity and SaaS tools. OneClickComply checks them against 21 CFR Part 11 and shows you exactly where you stand.
Fix & generate
OneClickFix remediates technical gaps in one click, and AutoComplete generates 21 CFR Part 11-aligned policies from your real environment.
Monitor & evidence
Continuous monitoring keeps you compliant, and our in-house audit team is on hand when you need expert guidance.
FDA 21 CFR Part 11 requirements
All nine sections of 21 CFR Part 11 across Subparts A to C, with the lettered paragraphs of the closed system, signature and password control sections listed individually.
| Reference | Requirement |
|---|---|
| 11.1 | Scope |
| 11.2 | Implementation |
| 11.3 | Definitions |
| 11.10 | Controls for closed systems |
| 11.10(a) | Validation of systems |
| 11.10(b) | Accurate and complete copies of records |
| 11.10(c) | Protection of records for retrieval throughout retention |
| 11.10(d) | Limiting system access to authorised individuals |
| 11.10(e) | Secure, time-stamped audit trails |
| 11.10(f) | Operational system checks |
| 11.10(g) | Authority checks |
| 11.10(h) | Device checks |
| 11.10(i) | Education, training and experience of personnel |
| 11.10(j) | Written policies on accountability for electronic signatures |
| 11.10(k) | Controls over systems documentation |
| 11.30 | Controls for open systems |
| 11.50(a) | Signature manifestations: name, date and time, and meaning |
| 11.50(b) | Controls on signature information in human readable form |
| 11.70 | Signature/record linking |
| 11.100(a) | Electronic signatures unique to one individual |
Always check the official 21 CFR Part 11 text for the exact wording.
21 CFR Part 11 FAQs
What is 21 CFR Part 11?
21 CFR Part 11 is the FDA regulation on electronic records and electronic signatures. It sets the criteria under which the FDA treats electronic records, and signatures applied to them, as trustworthy, reliable and equivalent to paper records with handwritten signatures. It was published on 20 March 1997 and took effect on 20 August 1997, and it covers system validation, audit trails, access controls, signature manifestations and identification code and password controls.
Who must comply with 21 CFR Part 11?
Any organisation that keeps or submits FDA-required records electronically must comply with 21 CFR Part 11. This includes pharmaceutical, biologics and medical device manufacturers, clinical trial sponsors, contract research organisations and laboratories. Part 11 applies to records created, modified, maintained, archived, retrieved or transmitted under FDA predicate rules, and to electronic submissions under the Federal Food, Drug, and Cosmetic Act and the Public Health Service Act.
What are the main requirements of 21 CFR Part 11?
The main requirements are in section 11.10, which lists controls for closed systems: system validation, accurate record copies, record protection, limited system access, secure time-stamped audit trails, operational, authority and device checks, trained staff, signature accountability policies and documentation controls. Sections 11.50 and 11.70 cover signature manifestations and signature to record linking, and sections 11.100 to 11.300 set rules for electronic signatures, identification codes and passwords.
What happens if you do not comply with 21 CFR Part 11?
Non-compliance is identified during FDA inspections and can lead to Form 483 observations and warning letters, and the FDA may question the reliability of data held in non-compliant systems. Because Part 11 supports underlying predicate rules such as good manufacturing practice and clinical practice requirements, data integrity failures can also lead to wider regulatory action under those rules. Part 11 itself does not set a fixed fine.
What audit trail does Part 11 require?
Section 11.10(e) requires secure, computer-generated, time-stamped audit trails that independently record the date and time of operator entries and actions that create, modify or delete electronic records. Changes must not obscure previously recorded information. The audit trail must be kept for at least as long as the records it covers and be available for FDA review and copying.
Is there a 21 CFR Part 11 certification?
No. The FDA does not certify systems or organisations as Part 11 compliant. Compliance is demonstrated by the regulated company through system validation, documented procedures and controls, and FDA inspection. Software vendors can describe Part 11 supporting features, but responsibility for compliance stays with the organisation that uses the system for regulated records.
How does 21 CFR Part 11 relate to ISO 27001 and SOC 2?
They overlap but are not interchangeable. ISO 27001 and SOC 2 cover information security controls such as access management, logging and change control, which support several Part 11 requirements. Part 11 adds FDA-specific obligations such as system validation, signature manifestations, signature to record linking and certifying electronic signatures to the FDA. A mature ISO 27001 or SOC 2 programme gives a strong base for the technical Part 11 controls.
Does OneClickComply support 21 CFR Part 11?
21 CFR Part 11 is mapped in OneClickComply's control library and is available on request rather than as a standard framework today. It can be used to link Part 11 access, audit trail and password requirements to controls and evidence you already hold. OneClickComply does not certify Part 11 compliance or replace computer system validation, which remains the regulated company's responsibility.
Related standards
All standards- HIPAA Administrative Simplification RegulationsRegulation · US
- NISPOM (32 CFR Part 117)Regulation · US
- NYDFS Cybersecurity Regulation (23 NYCRR Part 500)Regulation · US
- HIPAA Security RuleRegulation · US
- Unclassified Naval Nuclear Propulsion Information (U-NNPI)Regulation · US
- TSA Security Directive 1580/82-2022-01: Rail Cybersecurity Mitigation Actions and TestingRegulation · US
- FTC Safeguards Rule (GLBA, 16 CFR Part 314)Regulation · US
- 45 CFR 155.260 (ACA Exchange Privacy and Security)Regulation · US
Get 21 CFR Part 11 ready, not stressed